Thursday, January 29, 2009

Compliance News: TJC Standards and Scoring Changes for 2009

There have been some significant changes to The Joint Commission’s (TJC) standards and scoring for 2009. The Emergency Management (EM) requirements have been removed from the Environment of Care chapter and incorporated into their own EM chapter. The Life Safety Code® requirements, Statement of onditions™ (SOC™), and Interim Life Safety Measures (ILSM) have all been relocated to a new Life Safety (LS) chapter. While there are purportedly no new requirements as a result of all these changes, there are some subtle nuances that may be viewed as new requirements along with items that might have been implied in the past which are now specified. However, the most significant changes can be found in the scoring.

Compliance News: TJC Thresholds to Serve as Screens for PDA & CA Decisions

By Dean Samet, CHSP

In their December 2008 The Joint Commission Perspectives, Volume 28, Number 12, The Joint Commission (TJC) reported that at its October 2008 meeting, TJC’s Accreditation Committee (AC) approved the remaining component for the 2009 accreditation decision methodology which included elimination of the use of thresholds” as determinants of Conditional Accreditation (CA) and Preliminary Denial of Accreditation (PDA). Thresholds have been used by TJC for years to determine whether to invoke or recommend CA or PDA if and when an organization had exceeded a preset number of Requirements for Improvement (RFIs).

Compliance News: Sprinkler Obstructions

By Robert Trotter, CBO, CFM

The Joint Commission’s Life Safety Standard LS.02.01.10 states, “…buildings contain approved automatic sprinkler systems as required…” In order to determine where sprinklers are required facility managers should consult NFPA 13, Standard for the Installation of Sprinkler Systems.  Recently, TJC surveyors have recognized deficiencies related to sprinkler obstructions and noted such observations.  NFPA 13 states, “Sprinklers shall be installed under fixed obstructions over 4 foot wide such as ducts, decks, open grate flooring, cutting tables, and overhead doors.  Sprinklers are not required under obstructions that are not fixed in place such as conference tables.” The example shows sprinkler protection under an HVAC duct which was an obstruction that prevents sprinkler discharge from reaching the hazard.  Consult your licensed fire sprinkler contractor for assistance.

Compliance News: Beyond Level of Exit Discharge

By Robert Trotter, CBO, CFM

NFPA 101®, Life Safety Code® states in section 7.7.3 “Stairs shall be arranged so as to make clear the direction of egress to a public way.  Stairs that continue more than one-half story beyond the level of exit discharge shall be interrupted at the level of exit discharge by partitions, doors, or other effective means.”  The example shown is a barrier that restricts downward travel.  Upward travel to the rooftop may also require a barrier.  The LSC also prescribes provisions for signs.  Section 7.10.8.3.1 states,  “Any door, passage, or stairway that is neither an exit nor a way of exit access and that is located or arranged so that it is likely to be mistaken for an exit shall be identified by a sign that reads as follows: NO EXIT.”  The NO EXIT sign shall have the word NO in letters two inches high, with a stroke width of ⅜ inch, and the word EXIT in letters one inch high, with the word EXIT below the word NO, unless such sign is an approved existing sign.  The sign in the example may be an approved existing sign as it appears to be meeting the intent of the code.

Compliance News: Storage in Exit Enclosures

By Robert Trotter, CBO, CFM

Maintaining the means of egress is a critical role for any facility manager.  It is important to note that NFPA 101®, Life Safety Code® section 7.2.2.5.3.1 addresses storage in exit enclosures,“Open space within the exit enclosure shall not be used for any purpose that has the potential to interfere with egress.”  Clearly by
the examples shown, this storage arrangement has the potential to interfere with egress by leaving this stairway completely inaccessible should these stored materials catch on fire. Moreover, it also presents an opportunity for an incendiary fire.

Compliance News: Combustible Decorations

By Robert Trotter, CBO, CFM


Evaluation of combustible decorations is always difficult because interpretation of the requirement is subjective.  One person may believe the decorations are acceptable and do not constitute a hazard, while another may feel that the decorations are too much.  Regardless, combustible decorations must meet the requirements of the Life Safety Code®. For those organizations accredited by The Joint Commission, requirements for combustible decorations are found in the Life Safety Chapter. For example, the hospital accreditation program Standard LS.02.01.70 Element of Performance (1) states, “The hospital prohibits all combustible decorations that are not flame retardant. (For full text and any exceptions, refer to NFPA 101-2000: 18/19.7.5.4.)”  Both the new and existing health care occupancy chapters state, “Combustible decorations shall be prohibited in any health care occupancy unless they are flame-retardant. Exception:  Combustible decorations, such as photographs and paintings, in such limited quantities that a hazard of fire development or spread is not present.”

Monday, September 1, 2008

Finding Emergency Power System Vulnerabilities in Healthcare Facilities

By David L. Stymiest, P.E., CHFM, FASHE (in Touch Briefings)

Healthcare facilities can be put at risk when a power failure occurs unexpectedly, particularly if the facility management has not made contingency plans for that particular failure. This article discusses a comprehensive approach to identifying emergency power system vulnerabilities in healthcare facilities. Vulnerabilities are most easily found when one considers the elements discussed below, which also affect emergency power reliability.

It is important to consider designs that can maximise reliability to make sure that the potential for common-mode failures is minimised or eliminated. Commissioning and comprehensive initial acceptance testing of new systems must be utilised to verify that the entire system works as intended, and that all necessary emergency power loads are actually connected to the emergency power system. Commissioning and acceptance testing of modifications to existing systems can also verify that deleterious changes have not inadvertently reduced system reliability. The documentation of maximum demand loading from comprehensive load profile analysis will ensure that the system will not accidentally become overloaded at any point. Proactive fuel management processes, including fuel oil testing and treatment, ensure that the fuel oil does not have impurities that will adversely affect engine operation. It is important to maintain accurate documentation that is user-friendly and useful in responding to both internal and external power failures. There must be a proven ability to manage system shut- owns successfully and proactively, verifying that system knowledge and contingency planning are accurate and effective.

Friday, February 1, 2008

Power Players: Finding Emergency Power System Vulnerabilities

By David L. Stymiest, P.E., CHFM, FASHE (in Health Facilities Management)

Power failures often occur with little or no warning, leaving hospitals and other health care facilities vulnerable. Facilities professionals must have well-considered power failure procedures in place to deal with these emergencies; it is too late to develop them after the failure.

Knowledge of effective power failure planning concepts—including power failure vulnerability analyses, emergency power risk assessments and emergency power gap analyses—is essential for facilities professionals seeking to develop such procedures. Professionals are also urged to explore financial business continuity practices for more information on advanced power system reliability planning and analyses.

Read entire article here: Power Players

Tuesday, May 1, 2007

Prescription for Power: Advice on EP System Reliability

By David Stymiest, P.E., CHFM, SASHE (in Health Facilities Management)

Emergency power (EP) reliability means having EP available in sufficient quantity where, when and for whatever duration it is needed. That is a tall order but one that every health care facility faces.

How can facilities professionals improve EP system reliability? The EP reliability equation demands holistic management that includes all of the following elements:


Read entire article here: Prescription for Power

Friday, December 1, 2006

Power When It Counts

By David L. Stymiest, P.E., CHFM, FASHE (on FacilitiesNet.com)

Hospital maintenance and engineering departments must have programs in place to monitor and test their facilities’ emergency power systems. With the recent release of the Sentinel Event Alert 37, the bar is higher for all health care organizations accredited by the Joint Commission for the Accreditation of Healthcare Organizations (JCAHO).

Before the alert, the recordkeeping for many hospitals’ testing programs consisted mainly of generator loading and operating parameters, test times, and verification of transfer switch operation. Now managers must consider other issues, including test-related interactions with HVAC, vertical-transportation, and clinical systems and equipment.

Read entire article here: Power When It Counts

Saturday, July 1, 2006

Position of Power: Using an EPMS to Provide Electricity Savings, Reliability and Other Benefits

By Jason V. D’Antona, P.E., and David L. Stymiest, P.E., CHFM, SASHE, CEM (in Health Facilities Management)

Electrical Power Management Systems (EPMS) are quickly becoming commonplace in today’s health care facilities.

Microprocessor-based technology has become widely integrated into electrical distribution equipment, enabling easy connection into a facility EPMS. Moreover, nearly all new electrical distribution components can be prewired for EPMS at minimal cost.

But, despite the availability of this new equipment, implementing an effective EPMS can be a challenging task that requires strong collaboration between the facility manager, design team and system vendor. In the end, however, the effort will be worth it.

Read entire article here: Position of Power